Nissan Maxima QX

since 1993 release

Repair and operation of the car



Nissan Maxima QX
+ Cars of the Nissan Maxima brand
+ Maintenance instruction
+ Settings and routine maintenance
+ Engine
- Cooling systems, heating
   General information
   Antifreeze - general information
   Check of serviceability of functioning and replacement of the thermostat
   Check of a condition of fans of the cooling system and chains of their inclusion, replacement of components
   Removal and installation of a radiator and expanded tank of the cooling system
   Check of a state and replacement of the water pump
   Check of serviceability of functioning and replacement of the block of the sensor of the measuring instrument of temperature of cooling liquid
   Check of serviceability of functioning of a driving electric motor of the fan of a heater and condition of components of its electric chain, …
   Removal and installation of an electric motor of the drive of the fan of a heater
   Removal and installation of assembly of the control panel of functioning of a heater and conditioner of air, adjustment of a driving cable
   Removal and installation of the heat exchanger of a heater
   Check of serviceability of functioning and service of systems of heating and air conditioning
   Removal and installation of a receiver dehumidifier To/in
   Removal, service and installation of the K/V compressor
   Removal and installation of the K/V condenser
+ Power supply system and release
+ Engine electric equipment
+ Control systems of the engine
+ Transmission
+ Coupling and power shafts
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment

Cooling systems, heating

Specifications

General parameters
Volume of cooling liquid See the Head Nastroyki and routine maintenance
Effort of a tension of a driving belt See the Head Nastroyki and routine maintenance
Settlement pressure of a cover of a radiator, kgf/cm 2 0.8 - 1.0
Temperature of opening of the thermostat, °C
Beginning of opening 83
Full opening 91
Compressor of the air conditioning system
Type
Models 1993 and 1994 of of the issue. NVR 140S (rotational) productions of the ATSUGI company
Models since 1995 of the issue.
Except the Middle East V-6 of production of the CALSONIC company
Middle East DKS-16H of production of the ZEXEL company
Volume, cm 3 (NVR 140S) 140
Shift, cm 3/about
V-6
Move 184
Min 14.5
DKS-16H 167
Direction of rotation (all types) Clockwise (from the drive)
Drive Belt
Coolant
NVR 140S R-12
V-6 and DKS-H16 R-134a
Efforts of tightening of threaded connections Nanometer
Thermostat casing cover bolts
SOHC engines 16 - 21
DOHC engines 8.4 - 11.2
Bolts of fastening of the water pump
SOHC engines 16 - 21
DOHC engines 7 - 10
Bolts of fastening of a steering column 15 - 18